Hyundai Sonata LF: Seat Electrical / Seat Heater Repair procedures

Hyundai Sonata LF 2014-2019 Service Manual / Body Electrical System / Seat Electrical / Seat Heater Repair procedures

Inspection
Front Seat Heater
1.
Check for continuity and measure the resistance between terminals No 3 and No 6.


Standard value
Driver / Assists (cushion + back) : 1.58±10%

2.
Operate the seat heater after connecting the connector, and then check the thermostat by measuring the temperature of seat surface.

Standard value
1st : cushion : 36±2°C, back : 40±2°C
2st : cushion : 39±2°C, back : 45±2°C
3st : cushion : 42±2°C, back : 50±2°C

Front Seat Heater (Air Ventilation)
1.
Check for continuity and measure the resistance between terminals.


Standard value
Cushion (Teminal : 4-6) : 2.94?±10%
Back (Teminal : 5-6) : 2.71?±10%

2.
Operate the seat heater after connecting the connector, and then check the thermostat by measuring the temperature of seat surface.

Standard value
1st : cushion : 36±2°C, back : 40±2°C
2st : cushion : 39±2°C, back : 45±2°C
3st : cushion : 42±2°C, back : 50±2°C

Rear Seat Heater
1.
Check for continuity and measure the resistance between terminals No 1 and No 4.


Standard value
Rear seat : 2.82?±10%

2.
Operate the seat heater after connecting the connector, and then check the thermostat by measuring the temperature of seat surface.

Standard value
High (Cushion) : 38±2°C
Low (Cushion) : 42±2°C

    Seat Heater Schematic Diagrams

    C..

    Seat Heater Switch Components and Components Location

    C..

    Other information:

    Hyundai Sonata LF 2014-2019 Service Manual: Cylinder Block Repair procedures


    Removal Engine removal is required for this procedure. (Refer to Engine and transaxle assembly removal in this group) 1. MT : Remove the flywheel. (Refet to Cylinder Block - "Flywheel") 2. AT : Remove the drive plate. (Refet to Cylinder Block - "Drive Plate") 3...

    Hyundai Sonata LF 2014-2019 Service Manual: Temperature Control Actuator Repair procedures


    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the temperature control actuator connector. 3. Verify that the temperature control actuator operates to the cool position when connecting 12V to terminal 3 and grounding terminal 7...

    Categories

    read more

     
    Copyright © 2025 www.hsonatalf.org