| Inspection |
| 1. |
Connect the GDS on the Data Link Connector (DLC). |
| 2. |
Measure the output voltage of the MAPS at idle and IG ON.
|
| Removal |
| 1. |
Turn the ignition switch OFF and disconnect the battery negative (-) cable. |
| 2. |
Disconnect the manifold absolute pressure sensor connector (A). |
| 3. |
Remove the installation bolt (B), and then remove the sensor from the surge tank.
|
| Installation |
|
|
| 1. |
Install in the reverse order of removal.
|
Intake Air Temperature Sensor (IATS) Description and OperationDescription Intake Air Temperature Sensor (IATS) is included inside Manifold Absolute Pressure Sensor and detects the intake air temperature. To calculate precise air quantity, correction of the air temperature is needed because air density varies according to the temperature...
Troubleshooting Error ItemFailureSymptomInspection Items Detailed Inspections Relevant Parts/ComponentsScreen displayTFT-LCD screen does not turn on 1. Connector attachments 2. Components 1. Check the connector attachments 2. Check B+, IGN and GND wiring 3...
Replacement • Put on gloves to protect your hands. • When prying with a flat-tip screwdriver or use a prying trim tool, wrap it with protective tape, and apply protective tape around the related parts, to prevent damage...