Hyundai Sonata LF: Air Conditioning System / Evaporator Temperature Sensor Description and Operation

Hyundai Sonata LF 2014-2019 Service Manual / Heating, Ventilation and Air Conditioning / Air Conditioning System / Evaporator Temperature Sensor Description and Operation

Description
The evaporator temperature sensor will detect the evaporator core temperature and interrupt compressor relay power in order to prevent evaporator from freezing by excessive cooling. The evaporator temperature sensor has the Negative Temperature Coefficient (NTC). Electrical resistivity of NTC will increase with decreasing temperature and decrease with increasing temperature.

    A/C Pressure Transducer Repair procedures

    Inspection 1. Measure the pressure of high pressure line by measuring voltage output between terminal "1" and "2". 2. Inspect the voltage value whether it is sufficient to be regular value or not...

    Evaporator Temperature Sensor Repair procedures

    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the evaporator temperature sensor connector. 3. Measure the resistance between terminal "+" and "-" of the evaporator temperature sensor...

    Other information:

    Hyundai Sonata LF 2014-2019 Service Manual: Fuel Pump Control Module (FPCM) Schematic Diagrams


    C..

    Hyundai Sonata LF 2014-2019 Service Manual: Description and Operation


    Warning Lamp Activation Warning Lamp Behavior after Ignition On As soon as the operating voltage is applied to the SRSCM ignition input, the SRSCM activates the warning lamp for a LED lamp check. The lamp shall turn on for 6 seconds during the initialization phase and be turned off afterward...