Hyundai Sonata LF: Engine Control System / Heated Oxygen Sensor (HO2S) Specifications

Hyundai Sonata LF 2014-2019 Service Manual / Engine Control / Fuel System / Engine Control System / Heated Oxygen Sensor (HO2S) Specifications

Specification
HO2S [Bank 1/Sensor 1] (Linear type)
Item
Specification
Heater Resistance (?)
2.4 ~ 4.0 [20°C(68°F)]

Item
Specification
Heater Resistance (?)
Approx. 9.0 [20°C(68°F)]

HO2S [Bank 1/Sensor 2] (Binary type)
A/F Ratio (?)
Output Voltage(V)
RICH
0.6 ~ 1.0
LEAN
0 ~ 0.4

Item
Specification
Heater Resistance (?)
Approx. 9.0 [20°C(68°F)]

    Heated Oxygen Sensor (HO2S) Description and Operation

    Description Heated Oxygen Sensor (HO2S) consists of zirconium and alumina and is installed both upstream and downstream of the Manifold Catalytic Converter...

    Heated Oxygen Sensor (HO2S) Schematic Diagrams

    C..

    Other information:

    Hyundai Sonata LF 2014-2019 Service Manual: Relay Box (Engine Compartment) Components and Components Location


    C..

    Hyundai Sonata LF 2014-2019 Service Manual: Stop Signal Electronic Module Repair procedures


    Inspection 1. Fuse inspection Mount the test fuse to the switch fuse and relay fuse part to confirm a normal joint fit. 2. Inspection of connector by each part Check to see whether or not each connector has been damaged, or terminal surge, or incomplete connection has taken place [Engine room junction box] [Stop signal electronic module] [ABS/VDC control module] 3...

    Categories

    read more

     
    Copyright © 2026 www.hsonatalf.org