| Description |

If the ambient temperature is below 1.0°C (33.8°F), the A/C compressor will stop.
The compressor will operate manually.
|
Photo Sensor Repair proceduresInspection 1. Turn the ignition switch ON. 2. Connect the GDS. 3. Emit intensive light toward the photo sensor using a lamp, and check the output voltage change...
Ambient Temperature Sensor Repair proceduresInspection 1. Check the resistance of the ambient temperature sensor between terminals 1 and 2 whether it changes by changing the ambient temperature...
Replacement 1. Loosen the front door checker (B) mounting bolt. 2. Detach the clips, then remove the front door side weatherstrip (A). Tightening torque : 16.7 ~ 21.6 N.m (1.7 ~ 2.2 kgf.m, 12.3 ~ 15.9 lb-ft) 3. Install in the reverse order of removal...