Hyundai Sonata LF: Power Windows / Description and Operation
| Function of Safety Power Window |
When driver door power window auto-up switch is operated, safety function is activated.
| 1. |
Safety function condition
When detect the force of 100N (using the 10N/mm spring) during the window rising, window is reversed. |
| 2. |
Length of window reversing (except holding the auto-up switch)
| A. |
When detect the jamming during the 4mm ~ 250mm from top of the door.
> Window is reversed until 300mm from top of the door. 
|
| B. |
When detect the jamming over the 250mm from top of the door.
> Window is reversed until 50mm from jamming position. 
|
|
| 3. |
Length of window reversing (holding the auto-up switch)
| A. |
When detect the jamming during holding the auto-up switch.
> Window is reverse until 25mm from jamming position. |
| B. |
Auto-up function is not available during the 5 seconds from above condition.
> When holding the auto-up switch, window is operated as a manual-up function. (Safety function is not activated.) |
| C. |
When holding the auto-up switch after 5 seconds from above condition.
> Window is reverse until 25mm from jamming position. 
|
|
| 4. |
Safety function is not available area
Safety function is not available during the 4mm from top of the door. |
Initializing Method of the Safety Power Window
| 1. |
Initializing of Battery Connection
When the battery power is removed for over 5 minutes, safety power window switch need the initializing.
| (1) |
Power window operation before initializing
| A. |
Manual-Up/Down function is available |
| B. |
Auto-Up function is not available
(When holding the auto-up/down switch, window is operated as a manual-up/down.) |
|
| (2) |
Initializing method
Close the window in window open position, and holding the switch in window full close position over the 0.2 second.
(If start the closing the window in window full close position, initializing could be failed.) |
| (3) |
If initialize the safety power window in jamming status, could occur below conditions.
| A. |
Safety function is not available |
|
|
| 2. |
Initializing of fail safe mode
| (1) |
If the window moved by compulsion and motor have a problem,
power window switch could be entering the fail safe mode for user’s
safety. |
| (2) |
Power window operation in fail mode
| A. |
Auto/Manual-Down function is available |
| B. |
Auto/Manual-Up function is not available
(When auto/manual-up is operated, window is rising 20mm and is stopped the moving.) |
|
|
Other information:
ECM Terminal And Input/Output signal
ECM Terminal Function
Connector [C500-A]
Pin No.DescriptionConnected to1Injector (Cylinder #3) [High] control outputInjector (Cylinder #3)2Injector (Cylinder #4) [High] control outputInjector (Cylinder #4)3Injector (Cylinder #2) [Low] control outputInjector (Cylinder #2)4Electric Waste Gate Actuator (EWGA) DC Motor output (+)Electric Waste Gate Actuator (EWGA) 5Heated Oxygen Sensor (HO2S) [Bank 1/Sensor 1] heater control outputHeated Oxygen Sensor (HO2S) [Bank 1/Sensor 1]6-?7-8-?9Sensor ground Electric Waste Gate Actuator (EWGA) 10-?11-?12-13-?14Cooling fan relay [High] control outputCooling fan relay [High]15CVVT Oil Control Valve (OCV) [Bank 1/Exhaust] control outputCVVT Oil Control Valve (OCV) [Bank 1/Exhaust]16Injector (Cylinder #2) [High] control outputInjector (Cylinder #2)17Injector (Cylinder #1) [High] control outputInjector (Cylinder #1)18Injector (Cylinder #3) [Low] control outputInjector (Cylinder #3)19Electric Waste Gate Actuator (EWGA) DC Motor output (-) Electric Waste Gate Actuator (EWGA) 20Heated Oxygen Sensor (HO2S) [Bank 1/Sensor2] heater control outputHeated Oxygen Sensor (HO2S) [Bank 1/Sensor 2]21-?22-?23Engine Coolant Temperature Sensor (ECTS) signal inputEngine Coolant Temperature Sensor (ECTS)?24Sensor groundEngine Coolant Temperature Sensor (ECTS) 25-?26Fuel Tank Pressure Sensor (FTPS) signal inputFuel Tank Pressure Sensor (FTPS)27Fuel pump relay control output (NON-Smart key type)Fuel pump relayCanister Close Valve (CCV) control output (Smart key type)Canister Close Valve (CCV)28-?29-30-?31Ignition coil (Cylinder #3) control outputIgnition coil (Cylinder #3)32Ignition coil (Cylinder #1) control outputIgnition coil (Cylinder #1)33Injector (Cylinder #1) [Low] control outputInjector (Cylinder #1)34Fuel Pressure Control Valve (FPCV) [High] control outputFuel Pressure Control Valve (FPCV)35ETC motor [-] control outputETC motor36-?37Knock Sensor (KS) signal inputKnock Sensor (KS)38Sensor groundKnock Sensor (KS)39-40Brake Light switch signal inputBrake switch41-42-43-?44-?45CVVT Oil Control Valve (OCV) [Bank 1/Intake] control outputCVVT Oil Control Valve (OCV) [Bank 1/Intake]46Ignition coil (Cylinder #4) control outputIgnition coil (Cylinder #4)47Ignition coil (Cylinder #2) control outputIgnition coil (Cylinder #2)48Injector (Cylinder #4) [Low] control outputInjector (Cylinder #4)49Fuel Pressure Control Valve (FPCV) [Low] control outputFuel Pressure Control Valve (FPCV)50ETC motor [+] control outputETC motor51-?52Electric Waste Gate Actuator (EWGA) Feed beck signal Electric Waste Gate Actuator (EWGA) 53Brake Test switch signal inputBrake switch54-?55-56Electric load signal input [Defrost]Alternator57Alternator COM signal outputAlternator58Engine speed signal outputCluster59Cooling fan relay [Low] control outputCooling fan relay [Low] 60-
Connector [C500-K]
Pin No...
Components and Components Location
Components
1. Knob & boots asssembly2. Upper cover complete 3. Console front complete assembly4. Console rear complete assembly5. Console rear mounting bracket
Floor Console Assembly Components and Components Location
Component Location