| Oil Specification |
| 1. |
The R-134a system requires synthetic (ND8) compressor oil
whereas the R-12 system requires mineral compressor oil. The two oils
must never be mixed. |
| 2. |
Compressor (ND8) oil varies according to compressor model. Be sure to use oil specified for the model of compressor.
|
| 1. |
The oil should be free from moisture, dust, metal powder, etc. |
| 2. |
Do not mix with other oil. |
| 3. |
The water content in the oil increases when exposed to air.
After use, seal oil from air immediately. (R-134a Compressor Oil absorbs
moisture very easily.) |
| 4. |
The compressor oil must be stored in steel containers, not in plastic containers.
|
Oil total volume in system
ND8 (PAG): 80 ± 10 cc (2.82 ± 0.3 oz.) |
| 1. |
Open all the doors and engine hood. |
| 2. |
Start the engine and air conditioning switch to "ON" and set the blower motor control knob at its highest position. |
| 3. |
Run the compressor for more than 20 minutes between 800 and 1,000 rpm in order to operate the system. |
| 4. |
Stop the engine. |
Components and Components LocationComponent Location Index Engine Room [Theta 2.4 GDI] 1. Receiver-drier2. Condenser3. Service Port (High Pressure)4. Service Port (Low Pressure)5...
Specifications DescriptionSpecificationsLimitGeneralTypeIn-line, DOHC?Number of cylinders4?Bore77mm (3.0315in)?Stroke85.44mm (3.3638in)?Total displacement1,591 cc (97.09 cu.in)?Compression ratio9.5 : 1?Firing order1-3-4-2?Valve timingIntake valveOpensATDC 8°/BTDC 42°?ClosesABDC 69°/ABDC 19°?Exhaust valveOpensBBDC 40°/BBDC 0°?ClosesATDC 3°/ATDC 43°?Cylinder headFlatness of gasket surfaceLess than 0...
Removal • Put on gloves to protect your hands. • When prying with a flat-tip screwdriver, wrap it with protective tape, and apply protective tape around the related parts, to prevent damage. 1. Disconnect the negative (-) battery terminal...